  the information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. this documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. it is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. neither schneider electric industries sas nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. *prices are indicative nov 3, 2015 1 product data sheet characteristics LC1K0910M7 tesys k contactor - 3p(3 no) - ac-3 - <= 440 v 9 a - 220...230 v ac coil product availability: stock - normally stocked in distribution facility ?
2 price*: 75.00 usd main commercial status commercialised range of product tesys k product or component type contactor device short name lc1k contactor application motor control resistive load utilisation category ac-1 ac-3 ac-4 poles description 3p pole contact composition 3 no [ue] rated operational voltage <= 690 v ac 50/60 hz for signalling circuit 690 v ac 50/60 hz for power circuit [ie] rated operational current 9 a at <= 440 v ac ac-3 for power circuit 16 a (<= 158 f (70 c)) at 690 v ac ac-1 for power circuit 20 a (<= 122 f (50 c)) at <= 440 v ac ac-1 for power circuit motor power kw 4 kw at 660...690 v ac 50/60 hz 4 kw at 500...600 v ac 50/60 hz 4 kw at 480 v ac 50/60 hz 4 kw at 440 v ac 50/60 hz 4 kw at 380...415 v ac 50/60 hz 2.2 kw at 220...230 v ac 50/60 hz control circuit type ac 50/60 hz control circuit voltage 220...230 v ac 50/60 hz auxiliary contact composition 1 no [uimp] rated impulse withstand voltage 8 kv overvoltage category iii [ith] conventional free air thermal current 10 a at <= 122 f (50 c) for signalling circuit 20 a at <= 122 f (50 c) for power circuit irms rated making capacity 110 a ac for signalling circuit conforming to iec 60947 110 a ac for power circuit conforming to iec 60947 110 a ac for power circuit conforming to nf c 63-110 rated breaking capacity 70 a at 660...690 v conforming to iec 60947 110 a at 380...400 v conforming to iec 60947 110 a at 220...230 v conforming to iec 60947 80 a at 500 v conforming to iec 60947 110 a at 440 v conforming to iec 60947 110 a at 415 v conforming to iec 60947 [icw] rated short-time withstand current 20 a <= 122 f (50 c) >= 15 s power circuit 110 a 100 ms signalling circuit 90 a 500 ms signalling circuit 80 a 1 s signalling circuit 40 a <= 122 f (50 c) 3 min power circuit 45 a <= 122 f (50 c) 1 min power circuit 60 a <= 122 f (50 c) 30 s power circuit 80 a <= 122 f (50 c) 10 s power circuit 85 a <= 122 f (50 c) 5 s power circuit 90 a <= 122 f (50 c) 1 s power circuit associated fuse rating 10 a gg for signalling circuit conforming to vde 0660 10 a gg for signalling circuit conforming to iec 60947 25 a am for power circuit 25 a gg at <= 440 v for power circuit average impedance 3 mohm at 50 hz - ith 20 a for power circuit
3 [ui] rated insulation voltage 600 v for signalling circuit conforming to csa c22.2 no 14 600 v for power circuit conforming to csa c22.2 no 14 600 v for signalling circuit conforming to ul 508 690 v for signalling circuit conforming to iec 60947-5-1 690 v for signalling circuit conforming to iec 60947-4-1 690 v for power circuit conforming to iec 60947-4-1 600 v for power circuit conforming to ul 508 electrical durability 1.3 mcycles 9 a ac-3 at ue <= 440 v 0.18 mcycles 20 a ac-1 at ue <= 440 v mounting support plate rail standards bs 5424 iec 60947 nf c 63-110 vde 0660 product certifications csa ul connections - terminals screw clamp terminals 2 cable(s) 0...0 in2 (0.34...1.5 mm2) - cable stiffness: flexible - with cable end screw clamp terminals 2 cable(s) 0...0.01 in2 (0.75...4 mm2) - cable stiffness: flexible - without cable end screw clamp terminals 2 cable(s) 0...0.01 in2 (1.5...4 mm2) - cable stiffness: solid screw clamp terminals 1 cable(s) 0...0 in2 (0.34...2.5 mm2) - cable stiffness: flexible - with cable end screw clamp terminals 1 cable(s) 0...0.01 in2 (0.75...4 mm2) - cable stiffness: flexible - without cable end screw clamp terminals 1 cable(s) 0...0.01 in2 (1.5...4 mm2) - cable stiffness: solid tightening torque 11.5 lbf.in (1.3 n.m) - on screw clamp terminals - with screwdriver flat ? 6 mm 11.5 lbf.in (1.3 n.m) - on screw clamp terminals - with screwdriver philips no 2 operating time 10...20 ms coil energisation and no closing 10...20 ms coil de-energisation and no opening safety reliability level b10d = 20000000 cycles contactor with mechanical load conforming to en/iso 13849-1 b10d = 1369863 cycles contactor with nominal load conforming to en/iso 13849-1 mechanical durability 10 mcycles operating rate 3600 cyc/h complementary control circuit voltage limits 0.2...0.75 uc at <= 122 f (50 c) drop-out 0.8...1.15 uc at <= 122 f (50 c) operational inrush power in va 30 va at 68 f (20 c) hold-in power consumption in va 4.5 va at 68 f (20 c) heat dissipation 1.3 w auxiliary contacts type type instantaneous (1 no) signalling circuit frequency <= 400 hz minimum switching current 5 ma for signalling circuit minimum switching voltage 17 v for signalling circuit non overlap distance 0.02 in (0.5 mm) insulation resistance > 10 mohm for signalling circuit
4 environment ip degree of protection ip2x conforming to vde 0106 protective treatment tc conforming to din 50016 tc conforming to iec 60068 ambient air temperature for operation -13...122 f (-25...50 c) ambient air temperature for storage -58...176 f (-50...80 c) operating altitude 6561.68 ft (2000 m) without derating in temperature flame retardance requirement 2 conforming to nf f 16-102 requirement 2 conforming to nf f 16-101 v1 conforming to ul 94 mechanical robustness vibrations contactor opened 2 gn, 5...300 hz iec 60068-2-6 vibrations contactor closed 4 gn, 5...300 hz iec 60068-2-6 shocks contactor opened, on z axis 10 gn for 11 ms iec 60068-2-27 shocks contactor opened, on y axis 10 gn for 11 ms iec 60068-2-27 shocks contactor opened, on x axis 6 gn for 11 ms iec 60068-2-27 shocks contactor closed, on z axis 15 gn for 11 ms iec 60068-2-27 shocks contactor closed, on y axis 15 gn for 11 ms iec 60068-2-27 shocks contactor closed, on x axis 10 gn for 11 ms iec 60068-2-27 height 2.28 in (58 mm) width 1.77 in (45 mm) depth 2.24 in (57 mm) product weight 0.4 lb(us) (0.18 kg) ordering and shipping details category 22326 - ctr,k-line,ac,open,nonrev discount schedule i12 gtin 00785901079927 nbr. of units in pkg. 1 package weight(lbs) 0.40 product availability stock - normally stocked in distribution facility returnability y country of origin fr offer sustainability sustainable offer status green premium product rohs compliant - since 0633 - schneider electric declaration of conformity reach reference not containing svhc above the threshold product environmental profile available download product environmental product end of life instructions need no specific recycling operations contractual warranty period 18 months


▲Up To Search▲   

 
Price & Availability of LC1K0910M7

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X